Safety instructions
1-8
1070 080 059-101 (2001.04) GB
CAUTION
Damage to property through inappropriate or insufficient cooling of
the medium-frequency inverters!
Water-cooled medium-frequency inverters may only be operated
when the cooling water circuit is active! Condensation on water-car-
rying components must be prevented.
Damage to property through insufficient water quality in the cooling
water circuit!
Deposits in the cooling system may reduce the water flow, thus im-
pairing the performance of the cooling system with time.
Therefore, you should ensure that your cooling water has the follow-
ing properties:
D pH value :7 to 8.5
D Degree of hardness D
max
: 10 German degrees
(1 German degree = 1.25 British degrees = 1.05 US degrees =
1.8 French degrees)
D Chlorides : max. 20 mg/l
D Nitrates : max. 10 mg/l
D Sulfates : max. 100 mg/l
D Insoluble substances : max. 250 mg/l
Tap water usually meets these requirements. However, an algicide
should be added.
L Make sure that all contact surfaces are bright, i.e. free of paint, plastic coat-
ing or dirt/oxidation.
L Mount the device in a vertical position.