PSI 6200.XXX W1/W2
10-4
1070 080 059-101 (2001.04) GB
10.4 Technical data, PSI 6200.XXX W1/W2
Type 3-phase MF inverter, module designed for
recessed mounting
Weld timer integrated
I/O interface Slot for parallel, serial or fieldbus interface
Quality module Slot prepared for retrofitting
Degree of protection IP 20; designed for modular enclosure or for
installation in switchgear cabinets with IP 54
Inverter ambient temperature max. 55° C
Cooling W1/W2: water 4 l/min.; max. 30° C
Temperature monitoring integrated
Storage temperature -25° C to +70° C
Corrosion The ambient air must be free of acids, caus-
tic solutions, corrosive agents, salts and
metal vapors of any major concentration
Humidity Humidity class F as per DIN 40040;
20° C at 90% relative humidity;
40° C at 50% relative humidity (as per
VDE 0113);
Moisture condensation on the MF inverters
must be prevented.
Air pressure Any within a range of up to 2000 m above
sea level
Line voltage connection
grounded TN or TT system
W1: 400 V −20% to 480 V +10%; 50/60 Hz
W2: 480 V −20% to 690 V +10%; 50/60 Hz
Nominal system current;
max. continuous thermal current
220 A
Max. output current 1200 A
Max. secondary current; depending
on the transformer used
54 kA (PSG 3100)
Voltage supply;
Weld timer CPU;
I/O interface
24 V DC; min. 19 V DC up to max. 30 V DC
as per EN 61131-2, (external power supply),
or, alternatively, power supply from the weld
current system (internal power supply)
Clock frequency 1 kHz
Overvoltage protection MOV; Metal Oxide Varistor
Electrical connection, mains supply
and transformer
high-current bushing terminal;
max. 95 mm
2
Wire range 95 mm
2
Basic switchgear cabinet loss W1: 69 W
W2: 100 W
Max. ventilating and cooling loss
dissipated via external air-cooler
W1: 700 W
W2: 800 W
Switchgear cabinet loss at max.
power
W1: 210 W
W2: 240 W
Weight W1/W2: approx. 56 kg
Mounting position vertical or with its back on mounting plate
Page view 72
1 2 ... 68 69 70 71 72 73 74 75 76 77 78 ... 115 116