D7212GV3 | Operation and Installation Guide | 11.0 Arming Devices
.
Bosch Security Systems, Inc. | 10/10 | F01U143079-03 47
11.3 D279A Independent Zone Control
Any on-board or OctoPOPIT point can be
programmed so that the D279A Independent Zone
Control operates as independent point control (arming
and disarming the point).
Refer to Point Assignments in the D7212GV3
Program Entry Guide (P/N: F01U170808) for
programming information. Refer to the D279A
Operation and Installation Instructions (P/N: 46458)
for wiring and operation instructions.
11.4 Keyswitch
11.4.1 Description
A maintained or momentary contact arming station
(keyswitch) can be connected to master arm or
disarm any of the areas in the system. The keyswitch
is connected to an on-board or off-board point’s
sensor loop. Relays can be programmed to activate
arming status LEDs for keyswitch arming stations.
Refer to Relays in the D7212GV3 Program Entry
Guide (P/N: F01U170808)
11.4.2 Programming
Refer to Point Assignments in the D7212GV3
Program Entry Guide (P/N: F01U170808) for the
correct programming for points used for keyswitches.
11.4.3 Installation
For maintained switches, connect the EOL resistor for
the point at the keyswitch so that the switch opens the
circuit when it operates. A short on the circuit
produces an alarm if the area is armed and a trouble
if it is disarmed. Refer to Figure 21.
For momentary keyswitches, connect the EOL
resistor at the keyswitch point so that when the
keyswitch operates, it shorts the resistor. An open on
the circuit causes an alarm if the area is armed and a
trouble if it is disarmed. Refer to Figure 21.
11.4.4 Operation
Maintained Contact
If the point to which the keyswitch is connected is
programmed for a maintained contact, an open on the
arming circuit arms the area. All faulted points are
force armed, regardless of the entry in the FA Bypass
Max program item. Returning the circuit to normal
disarms the area. Refer to Area Parameters and Point
Assignments in the D7212 Program Entry Guide
(P/N: F01U170808)
Momentary Contact
If the point to which the keyswitch is connected is
programmed for a momentary contact, shorting the
arming circuit toggles the area’s arming state between
armed and disarmed. All faulted points are force
armed, regardless of the entry in the FA Bypass Max
program item. Refer to Point Assignments in the
D7212GV3 Program Entry Guide (P/N: F01U170808).
Silencing the Bell
To silence the bell (stop Alarm Bell output) if the
system is armed, position the keyswitch to disarm the
area. If the area is disarmed, turn the keyswitch once
to start the arming process. Turning the keyswitch a
second time stops the arming process and silences
the bell.
Figure 21: Keyswitch Wiring
1 - Maintained keyswitch
2 - Momentary keyswitch
3 - Common
4 - Point input
5 - 1 k
Ω
or 33 k
Ω
resistor
6- Open on a circuit arms the area
7 - Short on a circuit toggles the arming state
Use 1 k
Ω
EOL resistors if using one of the zones on the control panel or an OctoPOPIT. Use a 33 k
Ω
resistor if using a POPIT.