D7212GV3 | Operation and Installation Guide | 12.0 SDI Devices
48 Bosch Security Systems, Inc. | 10/10 | F01U143079-03
12.0 SDI Devices
12.1 Description
The D7212GV3 Control Panel can support a number
of accessory devices from the SDI Bus using
Terminals 29 through 32. Some devices include the
D1255RB and D1255 Keypads (refer to Section 11.0
Arming Devices on page 44), D9131A Parallel Printer
Interface Module, ITS-DX4020-G GPRS/GSM
Communicator, and DX4020 Network Interface
Module.
12.2 Installation
For complete installation instructions, consult the
operation and installation guide for the specific SDI
device. SDI devices connect to the control panel in
parallel (Table 19).
These devices can share power with the control panel
or be powered by a stand-alone power source.
Table 19: SDI Device Connections
D7212GV3 SDI Devices
Terminal Function Wire Color Function
32 POWER + Red +12.0 VDC
31 DATA BUS 1 Yellow Data
30 DATABUS B Green Data
29 COMMON Black Common
A stand-alone power supply powering the
SDI device must also be connected to a
common terminal on the control panel.
Do not connect the earth ground for the
stand-alone power supply to Terminal 10
on the control panel.
12.3 D9131A Parallel Printer Interface
Module
The Bosch Security Systems, Inc. D9131A Parallel
Printer Interface Module is a four-wire powered device
used to connect a standard parallel printer to a control
panel. The D7212GV3 can supervise one printer. A
separate D9131A Parallel Printer Interface Module is
necessary for each printer. The D9131A connects to
the printer using a standard parallel printer cable.
12.3.1 Switch Settings
Switches on the D9131A assign a unique address (17
to 19) for each printer. The address determines if the
printer is supervised, the area scope of the printers,
and the area to which the printer is assigned. Refer to
Printer Parameters in the D7212GV3 Program Entry
Guide (P/N: F01U170808) for a complete description
of addresses.
Table 20 shows the correct switch setting for Address
17.
Table 20: Printer Address Switch Settings
Printer Switch
1 2 3
4
5 6
17 ON ON ON ON ON ON
Switch 4:
ON = Header and form feed
OFF = No header and form feed
12.3.2 Supervision
Supervision includes:
Proper operation of the SDI bus
Proper connection of the printer cable between
the printer and the D9131A
Printer paper supply
Printer selected (on-line)
Printer power.
The control panel sends an SDI Failure Report to the
receiver if communication with the printer interface
fails. If an SDI failure occurs, SERVC PRINTER
appears at the keypad. The report to the receiver
includes the address of the troubled D9131A to
indicate which printer needs service.
If an SDI device is supervised and Terminal SDI A
becomes disconnected, the device can continue to
operate normally, depending upon environmental
conditions.
12.4 SDI Address 88 and 92
SDI Address 88 and 92 are available with the
D7212GV3 Control Panel and are used for several
different applications. Only one device can be
assigned to SDI Address 88 at a time. Likewise, only
one device can be assigned to SDI Address 92 at a
time.
12.4.1 Network Interface Modules
The Bosch Security Systems, Inc. DX4020 Network
Interface Module is a four-wire powered SDI device
that provides connection for two-way communication
over Ethernet networks to the D7212GV3.
For programming information on enhanced
communications, refer to the D7212GV3 Program
Entry Guide (P/N: F01U170808).
The DX4020 can be installed up to 305 m (1000 ft)
from the control panel using 0.8 mm (22 AWG) wire.
The ITS-DX4020-G GPRS/GSM IP Communicator
enables two-way IP or dialed communication over a
commercial GPRS/GSM network. Typical applications
are event reporting to a central monitoring station and
remote access to Bosch intrusion control panels.