Display Elements
a Alignment aides
b Reading
c Audio signal indicator
d Battery low indicator
e Indicator for changed zero point
f Unit of measure
Technical Data
Assembly
Inserting/Replacing the Battery
The measuring tool has two separate electric circuits: The grade measure-
ment and display are powered by a different battery than the laser.
Alkali-manganese batteries are recommended for the measuring tool.
f Remove the batteries from the measuring tool when not using it for
extended periods. When storing for extended periods, the batteries
can corrode and discharge themselves.
Inserting/Replacing the Battery for Grade Measurement
Carefully remove the battery lid 7 with the battery holder from the measur-
ing tool. Pay attention that neither the connection cables of the battery nor
the battery lid become damaged. Damage on the supporting surfaces of the
battery compartment 7 can lead to faulty measurements.
Connect the battery to the battery tray observing the correct polarity. Insert
the battery lid with the battery tray into the measuring tool in such a manner
that the connection cables are not pinched.
When switching on the grade measurement for the first time after changing
the battery, all display elements light up for 1 s and an audio signal sounds.
All saved settings (measuring mode, set unit of measure) are deleted when
changing the battery.
When the battery low indicator d lights up, the battery must be replaced.
Inserting/Replacing the Batteries for the Laser
Fold out the battery lid 20 and insert the batteries. When inserting, pay at-
tention to the correct polarity according to the representation on the inside
of the battery lid.
When the laser no longer lights up, the batteries must be replaced.
Digital level GIM 60 L
Article number
3 601 K76 300
Measuring range
0–360° (4x90°)
Measuring accuracy
–0°/90°
–1°89°
± 0.05°
± 0.2°
Working range of laser
1)
30 m
Levelling accuracy of laser
± 0.5 mm/m
Clearance of laser exit bottom edge of
measuring tool
24 mm
Laser class
2
Laser type
635 nm, <1 mW
Laser beam diameter (at 25 °C) approx.
at 5 m distance
at 10 m distance
3.5 mm
6mm
Operating temperature
–10 °C...+50 °C
Storage temperature
–20 °C...+70 °C
Relative air humidity, max.
90 %
Tripod mount
1/4"
Batteries
Grade measurement
Laser operation
1x9V6LR61
2x1.5VLR03 (AAA)
Operating life time, approx.
Grade measurement
Laser operation
300 h
20 h
Weight according to EPTA-Procedure 01/2003
0.9 kg
Dimensions (length x width x height)
600x27x59mm
1) The working range can be decreased by unfavourable environmental conditions
(e.g. direct sun irradiation).
The measuring tool can be clearly identified with the serial number 23 on the type plate.
OBJ_BUCH-1628-002.book Page 15 Monday, August 27, 2012 12:22 PM
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 221 222

Comments to this Manuals

No comments