22 en | Installation UHI/UHO Series
F.01U.026937 | V 2.0 | 2007.01 User Manual Bosch Security Systems
5. Connect the supply power wires to the terminal block. See
Figure 4.8. Strip no less than 6 mm (0.25 in) and no more
than 8mm (0.31 in) of insulation away from the wire. Be
sure not to nick the wires.
6. Cut the power cord on 120 VAC and 230 VAC camera mod-
els; leave enough cable to allow connection to the terminal
block. Strip no less than 6 mm (0.25 in) and no more than
8 mm (0.31 in) of insulation away from the wire. Be sure
not to nick the wires. Connect these wires to the connec-
tors provided on the terminal block. See Figure 4.8.
!
CAUTION!
Be sure to securely tighten all fittings to ensure a liquid-tight
seal. Failure to do this could allow water to enter the housing
and damage electronic parts, camera, and lens.