Bosch AHS 54-20 LI Instruction Manual Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 164
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
English | 27
Bosch Power Tools F 016 L70 590 | (30.6.09)
During the charging procedure, the three green
LEDs light up one after the other and briefly go
out. The battery is fully charged when the three
green LEDs light up continuously. The three
LEDs go out again approx. 5 minutes after the
battery has been fully charged.
Temperature Control Indicator
The red LED 17 signals that the battery or the
electronics of the garden product (with battery
inserted) are not within the optimum tempera-
ture range. When this occurs the garden prod-
uct will not operate or not at full capacity.
Temperature Control of the Battery
The red LED 17 flashes when pushing button 15
or pressing the On/Off switch 6 (when the bat-
tery is inserted): The battery is not wihin the
temperature range for operation of 10 °C to
+60 °C.
The battery switches off at a temperature above
70 °C until the optimum temperature range is
reached again.
Temperature Control of the Garden Product
Electronics
The red LED 17 lights up continuously when
pressing the On/Off switch 6: The temperature
of the garden product electronics is below 5 °C
or above 75 °C.
At a temperature above 90 °C, the electronics
of the garden product switch off until the tem-
perature is within the allowable temperature
range again.
Troubleshooting
The following chart lists problem symptoms, possible causes and corrective action, if your garden
product does not operate properly. If these do not identify and correct the problem, contact your
service agent.
f Warning: Switch off and remove the battery prior to any troubleshooting.
Problem Possible Cause Corrective Action
Hedgecutter does not operate Battery discharged Recharge battery; also see
“Battery Charging”
Battery not fully connected Ensure both locking levels are
engaged
Hedgecutter operates intermit-
tently
Internal wiring of garden prod-
uct damaged
Contact Service Agent
On/Off switch defective Contact Service Agent
Motor reverses repeatedly then
stalls after 3 s.
see “Working Advice” (Anti
Blocking)
Motor runs but blades remain
stationary
Internal fault Contact Service Agent
Cutting blade hot Cutting blade dull Have blade sharpened
Cutting blade has dents Have blade inspected/over-
hauled
Too much friction, due to lack
of lubricant
Apply lubricant spray
OBJ_BUCH-948-003.book Page 27 Tuesday, June 30, 2009 2:04 PM
Page view 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 163 164

Comments to this Manuals

No comments