• DOK-POWER*-KDV*2.3****-ANW1-EN-E1,44 • 06.97
1. The design of INDRAMAT's modular AC drive system
1.1. The design of the KDV 2.3 supply module
The threephase bridge rectifies the threephase mains AC voltage and provides
the DC high voltage for the drives.
When the drives are in generator-mode, the regenerated energy is absorbed
by the bleeder and transformed into heat.
The buffer capacitance provides sufficient smoothing.
The KDV 2.3 provides the +24V and ±15V for all attached drive modules.
In the event of a power failure, the signal voltages receive their power from the
DC bus. This means that the drive electronics can still function, when the
drives are in generator mode.
The KDV 2.3 is equipped with extensive monitoring functions. These
communicate with the drive modules via the signal voltage bus.
The Bb1 contact is of greater significance to drive system readiness. Power
can only be switched on when this contact is closed.
Power supply to the
drives
Power supply to the
electronics
Monitoring the drive
system
Supply and drive
monitoring
drives ready
supply ready
&
Bb1
230 V AC
L1
L3
L1
L2
L3
3 x 230 V
smoothing choke
DC
DC
300 V DC
to supply the
drives
FSKDV23
=
~
Figure 1.2: The design of the KDV 2.3 supply module
Page view 5