WATER SUPPLY
The Worcester Greenstore cylinder has an optimum working
pressure of 3 bar (regulated by the inlet control set) and is
capable of delivering upto 50 litres per minute.
The maximum possible water demand should be assessed
taking into consideration that both hot and cold services are
supplied simultaneously from the mains.
The water supply should be checked to ensure it can meet
these requirements. If necessary consult the local water
authority regarding the likely pressure and flow rate availability.
If measuring the water pressure note that a high static (no
flow) mains pressure is no guarantee of good flow availability.
In a domestic installation 1.5 bar and 25 l/m should be
regarded as the minimum requirement. The maximum mains
pressure for the inlet control is 16 bar.
Consideration should be given to upgrading existing 1/2”
(15mm) cold mains pipework to a larger size if the
recommended minimum pressure/flowrate is not being
achieved.
SITING THE UNIT
Outlets that are above or at some distance from the Greenstore
cylinder, can still be supplied with water.
Outlets above the Greenstore cylinder will reduce the outlet
pressure available by 0.1 bar for every 1 metre of height
difference.
Site the unit to minimise “dead leg” distances especially to the
point of most frequent use.
The unit should be protected from frost. Particular care is
needed if siting in a garage or outbuilding. All exposed
pipework must be insulated.
Greenstore cylinders must be installed upright on a flat base
capable of supporting the weight of the cylinder when full of
water
(see technical specification section for weights).
The discharge pipework from the safety valves should fall
continuously and terminate safely.
SCHEMATIC DIAGRAM
Worcester Bosch Greenstore
3
Notes:
The pressure reducing valve, non return valve and expansion
relief valve are combined together in the inlet control set.
Consideration should be given for servicing and repair, when
siting the cylinder.
The cylinder position should be taken into consideration
when siting the Heat Pump.