TECHNICAL SPECIFICATION
Worcester Greenstore
TECHNICAL SPECIFICATIONS 7
Worcester Bosch Greenstore
Primary
Heating
Flow
Primary Heating Return
Return to
Solar Collector
Flow from
Solar Collector
Domestic Hot
Water Outlet
Mains Water
Inlet
Sacrificial
Anode
Primary
Tank
Solar Heat
Exchanger
Solar High
Limit Stat
pocket
GT3
Heat Pump
HW Sensor
pocket
Solar
Sensor
pocket
Temperature/Pressure
Relief Valve
Solar Sensor
and
Solar High
Limit Stat
cable entry
GT3 Heat Pump
HW Sensor
cable entry
180/280 LITRE CYLINDERS WITH SOLAR COIL
Air Vent
Connecting hot water sensor GT3
Before carrying out any electrical connections, ensure that
the Heat Pump is isolated from the mains supply.
Remove the Heat Pump front cover and route the sensor
cable from the back of the Heat Pump, laying the sensor
cable onto the cable tray. Connect the sensor to terminals
GT3X on the terminal card.
Remove the cylinder front cover. Feed the sensor cable
through the grommet of the right-hand cable entry, on top
of the cylinder. Fully insert the sensor probe into the GT3
sensor pocket, as indicated on the diagram above. Replace
the cylinder front cover.