Bosch DLR165 Service Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
-7-
Digital Laser Rangefinder DLR165K
Article number 3 601 K16 011
Dimensions 2 1/4" x 4" x 1 1/4" (58 x 100 x 32 mm)
Measuring range
A)
0.05 ... 50 m
(2 in ... 165 ft)
Distance measuring accuracy
typical accuracy ±1.5 mm (±1/16 in)
accuracy range 1.5 mm to 3 mm (±1/16 in to 1/8 in)
B
Measuring duration
typical
<0.5 s
maximum 4 s
Lowest indication unit 1/16 in; 0.005 ft; 1 mm
Operating temperature (+14° F … + 122° F)*
10 °C ... +50 °C*
*Continuous measurement mode, max. +40 °C (104 °F)
Storage temperature (– 4 °F ... –158 °F)
–20 °C ... +70 °C
Relative air humidity, max. 90 %
Laser class 2
Laser type 635 nm, <1 mW
Laser beam diameter (at 25 °C/77
°F), approx.
at 10 m (33 ft) distance 6 mm (1/4 in)
at 50 m (165 ft) distance 30 mm (1 3/16 in)
Batteries 4 x 1.5 V LR03 (AAA)
Rechargeable battery 4 x 1.2 V KR03 (AAA)
Battery service life, approx.
Individual measurements, approx.
30000
Continuous measurement mode, approx. 5 Hours
Automatic switch-off after approx.
Laser 20 s
rangefinder (without measurement) 5 min
Weight according to EPTA-Procedure 01/2003
0.18 kg (6.35 oz)
Protection class (excluding battery compartment) IP 54 (dust and splashwater protected)
Technical Data
13 On/Off button
14 Extension pin
15 Latch of the extension pin
16 Latch of battery lid
17 Battery lid
18 Serial number
19 Laser beam outlet
20 Reception lens
21 1/4" threaded hole for mounting optional
tripod
*
22
Laser viewing glasses *
23
Laser target plate*
24
Protective case
25 Hand strap
26 Hand strap mounting post
DISPLAY ELEMENTS
a
Battery indication
b Measured value/result
c Unit of measure
d Measurement reference point
e Laser switched on
f Individual measured value (for length
measurement: result)
g Variable measuring modes
Length measurement
Area measurement
Volume measurement
Indirect length measurement
h Measured value stored
* Optional Accessories
A) The working range increases depending on
how well the laser light is reflected from the
surface of the target (scattered, not reflective)
and with increased brightness of the laser
point to the ambient light intensity (interior
spaces, twilight). In unfavorable conditions
BM 1609929K02 03-07 3/5/07 1:41 PM Page 7
Page view 6
1 2 3 4 5 6 7 8 ... 32

Comments to this Manuals

No comments