D9412GV4/D7412GV4/D7212GV4 Setting Up Points and Outputs | en 13
Bosch Security Systems, Inc. Quick Reference Guide F01U215242 | 01 | 2011.10
6 Setting Up Points and Outputs
6.1 Using the Relay Option Within Point Assignments
Relay Programming allows any one point or several points to latch a single relay through
software when the selected point generates an alarm. Relays are number 1 through 8 and are
programmed by entering the number of the relay (1 - 8) in the Relay column in Point
Assignments. This relay latches on a generated alarm and resets after acknowledging and then
clearing the alarm from memory.
Table 6.1 Actual Relays Latched by Control Panel Type
Table 6.2 D8129 Switch Settings for All Control Panel Types
Relay
D8129 Actual Relay Number
D7412GV4/D7212GV4
1
D9412GV4
2
19 73
210 74
311 75
412 76
513 77
614 78
715 79
816 80
1
For the D7412GV4 and D7212GV4, connect to Terminal 28 for data (Zonex 1 Out).
2
For the D9412GV4, connect to Terminal 26 for data (Zonex 2 Out).
Switch Number Setting
1ON
2OFF
3ON
4ON
NOTICE!
Programmers must be aware of the following considerations:
Do not use relays designated within Point Assignments for multiple functions. For
example, Relays 73 through 80 on the D9412GV4 should not be used for relay-follow-
point or area-wide or panel-wide relays.
Relays should not be selected to follow points programmed as Invisible Points.