Signal LED 2 flashes red over a large measuring area on the wall
(warning of “live” cables)
Improper grounding
of the wall
With your free hand, touch the wall at a distance of
20 –30 cm from the measuring tool to ground the
wall.
“Live” cable is not found
No/atypical voltage
on the cable
Add voltage to the cable, for example by turning on
light switches assigned to it. The detection of ca-
bles with AC voltages outside of the range
110 –240 V, 5060 Hz is not reliably possible.*
Cable is located too
deep
The scanning depth is dependent on the building
material and may be less than the maximum scan-
ning depth.*
Cable runs in
grounded metal pipe
Use the measuring tool to locate the metal pipe.
Measuring tool is not
grounded
Hold the measuring tool firmly without gloves. Do
not stand on insulating ladders or scaffolding. Do
not wear insulating footwear.
Screened-off build-
ing material or high
air humidity
A reliable detection is not possible with metallic or
moist building materials (e.g.at high air humidity).*
Metal object is not located
Metal object is locat-
ed too deep
The scanning depth is dependent on the building
material and may be less than the maximum scan-
ning depth.*
Metal object is too
small
The scanning depth is dependent on the building
material and may be less than the maximum scan-
ning depth.*
Uncoordinated flashing in colours green, yellow, red
Interference caused
by electric or mag-
netic fields
Keep your distance from devices emitting strong
electric or magnetic fields (e.g. computers, switch
mode power supplies).
Cause Corrective Measure