20 en | Installing the Pipe Mount AutoDome Pipe Mount
F.01U.251.410 | 1.0 | 2011.08 Installation Guide Bosch Security Systems, Inc.
The following table lists the Power Supply Box connectors:
Table 2.1 Power Box Connections
Fuse Specifications
Volts XF101 Mains XF102 Camera XF103 Heater
24 V T 5.0 A T 2.0 A T 3.15 A
115 V T 1.6 A T 2.0 A T 3.15 A
230 V T 0.8A T 2.0 A T 3.15 A
No. Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6
Ground Grounding Screw
P101 115/230 VAC or
24 VAC Power In
Line NC Neutral
P105
1
Control to Dome
(Fiber Optic
Model)
C-
(Biphase)
C+
(Biphase
)
Earth
Ground
RXD (+)
(RS-232/485)
TXD (-)
(RS-232/485)
Signal
Ground
P106
1
Control In/Out
(Optional)
C-
(Biphase)
C+
(Biphase
)
Earth
Ground
RXD (+)
(RS-232/485)
TXD (-)
(RS-232/485)
Signal
Ground
P107 24 VAC Power to
Dome Plug
Dome
24 VAC
Dome
24 VAC
Earth
Ground
Heater
(24 VAC)
Heater
(24 VAC)
1. Applicable to VG5 600 and 100 Series AutoDomes only.