D9412GV4/D7412GV4/D7212GV4 Reporting Format Definitions | en 21
Bosch Security Systems, Inc. Quick Reference Guide F01U215242 | 01 | 2011.10
10 Reporting Format Definitions
Modem IIIa
2
Event Modem IIIa
2
Code
D6500 Mode
Modem IIIa
2
Code
Bosch SIA Mode
Contact ID Event Contact ID
Code
A point supervisory condition
occurred
Jsppp NriaBSppp 24 hour Non-Burglary 1 150 aa ppp
A valid local access occurred RsF01 NLS Successful Download/
Access
1 412 00 000
A valid remote access callback
occurred
RsssF NphhhRS Successful Download/
Access
1 412 00 000
A valid remote access occurred RsssF NRS Successful Download/
Access
1 412 00 000
AC Fail – mains power supply Pssss NAT AC Loss 1 301 00 000
AC Restore – mains power
supply
Rsss0 NAR AC Loss 3 301 00 000
Access Denied – Door Secured ADsppp Nria/idiiiDZppp or
Nria/idiii/
ssxDZppp
Access Denied 1 421 aa uuu
Access Denied – Interlocked ADsppp Nria/idiiiDWppp or
Nria/idiii/
ssxDWppp
Access Denied 1 421 aa uuu
Access Denied – No rights in
area by card
ADsppp Nria/idiiiDVppp or
Nria/idiii/
ssxDVppp
Access Denied 1 421 aa uuu
(NEW) Access Denied - No
rights in area by passcode
ADsppp Nria/idiiiDVppp Access Denied 1 421 aa uuu
Access Denied – Unknown ID ADsppp NriaDDppp Access Denied 1 421 aa uuu
Access Granted AGsppp Nria/idiiiDGppp or
Nria/idiii/
ssxDGppp
Access Report by User 1 422 aa uuu
Add Card to a User NsD30 NidiiiDAuuu Local Only Local Only
(NEW) Add Key Fob to User
(Assign Card Event)
NsD30 NidiiiDAuuu Local Only Local Only
Alarm Asppp NriaBAppp Burglary 1 130 aa ppp
Alarm Cross Point Asppp NriaBMppp Burglary 1 130 aa ppp
Alarm Exit Error Asppp Nria/idiiiEAppp Entry/Exit 1 134 aa ppp
Alarm with Recent Closing Asppp Nria/CRppp Entry/Exit 1 459 aa uuu
All Points Tested by User RsssF NRilTC Local Only Local Only
All SDI devices are missing,
power is shorted
TsssD NpidddET Expansion Module Failure 1 333 00 000
All SDI devices are restored,
power is normal
RsssD NpidddER Expansion Module Failure 3 333 00 000
An individual SDI device is
missing.
TsssD NpidddEM Expansion Module Failure 1 333 00 000
An individual SDI device is
restored.
RsssD NpidddEN Expansion Module Failure 3 333 00 000
An invalid remote access
callback occurred
TsssF NphhhRU Unsuccessful Access 1 413 00 000
An invalid remote access
occurred
TsssF NRU Unsuccessful Access 1 413 00 000
Area Watch End NsD52 Nria/idiiiiTZ Local Only Local Only
1
zzz indicates an SDI, or SDI2 device address value, or network trouble condition. Reference Table 10.2 for more