ICP-CC404 | Installation Guide | 22.0 Programming Sheets
86 Bosch Security Systems, Inc. | 12/08 | F01U089401-02
Location
Function
Options/Notes
Default/
Programming Entry
8
175
Ring Count
Refer to page 49
0 Control panel does not answer
1 to 13 Number of rings until control panel answers
14 Answering machine bypass 2
15 Answering machine bypass 1
0
176
Telephone Line Fail Options
Refer to page 49
1 Display FAULT indicator when telephone line fails
2 Sound alarm when system arms
4 Sound alarm when system disarms
Options 2 and 4 must be used with Option 1 (for example, program 1, 3, 5, or 7).
9
177
Dialer Options 1
Refer to page 50
1 Dialer reporting functions allowed
2 Remote arming by telephone allowed
4 Answering machine bypass only when armed
8 Bell 103 used for FSK format (Disabled = CCITT V21)
0
178
Dialer Options 2
Refer to page 50
1 Open/Close Reports only if previous alarm
2 Open/Close Reports for STAY Mode 1 and STAY Mode 2
4 Delay siren until transmission complete
8 Extend handshake wait time from 30 sec to 60 sec
0
179
Dialer Options 3
Refer to page 51
1 Set DTMF dialing pulses to 1 digit/sec
2 Reserved
4 Change decadic dialing to 60/40
8 Reserved
3
180
Alarm Link Options
Refer to page 40
1 Upload/download allowed
2 Call back phone number required for upload/download
4 Exit from upload/download connection on alarm
8 External modem module (CC811) required
1 2 3 4
181 to 184
Installer Code