Installation Instructions
Remote Controller
• Applicable Model
Remote controller
RCM3211
Main
The appliance BC3200RA is preset to 55°C and can be adjusted by connecting the connector of
the harness to 50°C, 75°C, and 85°C. And it can be adjusted by programming the CPU on the
PCB to 40°C, 60°C, and 65°C. BC3200RA5 is preset to 50°C and can be adjusted by connecting
the connector or programming the CPU on the PCB to 40°C, and 42°C .
Refer to the following for the setup method. When it set to 60°C or higher, the water is very hot,
so make sure that a mixing valve is installed.
* Up to three remote controllers can be connected. Additional remote controllers cannot be con-
nected by themselves.
The remote controller must be installed in accordance with the installation manual enclosed in the package.
Temperature settings without remote controller.
* Factory Default Setting
1. Disconnect electrical power to the water heater.
2. Remove the front cover of the water heater (4 screws).
3. Connect "WATER TEMPERATURE ADJUSTMENT CONNECTOR" tag
connector to "A" or "B" or "85°C (50°C)" tag connector as shown on the right.
(Refer to the table below)
Modification procedure of temperature setting to 50°C, 75°C, and 85°C.
(40°C and 42°C in case of BC3200RA5)
BC3200RA
55°C
50°C
75°C
85°C
BC3200RA5
50°C
40°C
42°C
50°C
Connector
Not connect
A
B
85°C (50°C)
4. Replace the front cover of the water heater (4 screws).
5. Reconnect electrical power to the water heater
"A" tag "B" tag
"85°C (50°C)" tag
WATER TEMPERATURE
ADJUSTMENT CONNECTOR
WATER TEMPERATURE
ADJUSTMENT CONNECTOR
B
A
85 C (50 C)
Page view 18