Installation Instructions
Item
Distance from combustibles
Maintain the following clearances
from both combustible and
non-combustible materials.
• If the unit will be installed in the vicinity of
a permanent kitchen range or stove that
has the possibility of generating steam
that contains fats or oils, use a dividing
plate or other measure to ensure that the
unit is not exposed to air containing such
impurities.
* The dividing plate should be noncombus-
tible and the width must exceed that of
the device.
* Do not remove mounting brackets to
reduce air gap at rear.
In Accordance with AS5601
Maintain the following clearances to any
opening in any building:
1.5m below and 500mm horizontally from
any door, window or gravity air inlet. 1m
above any forced air inlet.
500mm below an overhang.
In accordance with AS5601
Check Illustration
Range
Exhaust hood
Dividing plate
300mm Indoor
500mm Outdoor
600mm Outdoor
100mm Indoor
500mm Indoor
600mm Outdoor
If possible, leave 200mm or more on ei-
ther side of the unit to facilitate inspec-
tion.
If possible, leave 600mm or more in front
of the unit to facilitate maintenance
and service if necessary.
Securing of space for
repair/inspection
600mm
or more
200mm
or
more
200mm
or
more
Min: 75mm
Min: 75mm
Outdoor Clearances to any Opening
into Any Building
1000mm
500mm
1500mm
(unit: mm)
(unit: mm)
(unit: mm)