DS2020
User’s Guide
VOLT METER
RANGE : -150V - +150V
CH1
13.4
MIN :0.00V MAX :13.5V
CH2
2.66
MIN :2.08V MAX :3.26V
2.DTY 3.FRQ 4.ALL 5.AMP
ILL. 4-2 Volt Meter
3) From the menu in the bottom window, you can choose other multimeter
function by pressing the corresponding number key. It is not necessary to
return to the upper menu to change the mode.
a. [2. DUTY]: Changes to Duty Cycle mode
b. [3. FREQ]: Changes to Frequency mode
c. [4. ALL]: Changes to Show All mode (Volt + Duty Cycle + Frequency)
d. [ENTER]: Resets Min. and Max. values
4) Calibration
If the voltage values are not equal to zero when the probes are not attached to
any voltage source, the voltage output may not be correct. If this occurs,
calibration is necessary.
For proper calibration, connect the probes of each channel to the ground port
of the 4-channel adaptor and then press the [0] key.
3. Duty Cycle
A. Duty Cycle