Chapter 4
Chapter 4 - 13
while engine is idling, and it will make engine stall or unstable.
c Testing a fan or an injector is easy to check the proper reaction as it
generates distinctive changes in vehicle condition such as fan whining or
unstable idling. However, valves or motors are generally tested while
engine is stopped and all you can hear may be a small and unclear
electric buzzing sound. Test in a quite place and observe the test
results carefully.
d When the test is completed, the [TEST COMPLETE] message will be
displayed. You can choose other actuators by using the [] and []
keys. Press the [ESC] key to quit test mode.