Page view 124
Baum Tools Unlimited
Page 42
DS2020
User’s Guide
NOTICE
You will find the inscription 'This side to the spark plug' on one side of the
clamp. Connect the clamp to the spark plug cable of cylinder #1 so that the
inscribed side faces the #1 cylinder spark plug. The spark plug that is nearest
to the generator is usually the #1 plug.
When the clamp is connected properly and the clamp picks up the trigger well,
then DS2020 will indicate it by flickering the ground mark () on screen.
When the clamp is not connected properly, a waveform may still be displayed but
without or incorrect cylinder numbers. In case the high tension cable is not
available or the #1 cylinder doesn't ignite, the clamp should be connected to the
spark plug cable of the other cylinder. The ignition order will then be determined.
DS2020 recognizes the cylinder to which the trigger pickup clamp is
connected to be Cylinder #1. The ignition order of 4-cylinder engines is usually 1-
3-4-2. For example, if the clamp is connected to cylinder #3, the ignition waveform
will be displayed in a row as 3-4-2-1 while DS2020 still displays the
2) Primary Ignition Signal
Connect the probe with needle to the negative (-) line of the PRIMARY
ignition coil
Plug the other end to
DS2020
's channel 1 port
ILL. 4-3. Cable Connection for Primary Ignition Pattern