6.1.5 Maximum Security Arming
Maximum security arming is used when no one is still in the building, all zones are to be armed, an exit delay is
in effect, but no entry delay is in effect so an alarm does occur upon entry.
The green Status LED must be lit and, if using a text keypad, “Ready to Arm” must be displayed. If the green
LED is not on or the keypad displays “Not Ready,” you must use other methods to arm the system (refer to Section
6.2.2 Force Arming on page 13 or Section 6.2.3 Zone Bypass on page 14).
Table 7: Maximum Security Arming
Equipment Command Sequence What Happens What To Do
Text Keypad LED
Keypad
[PIN][No Entry][On] The red Armed LED flashes.
“Armed Instant” is displayed. *
“Exit Now” is displayed during the exit-
delay period. *
A single beep sounds.
The red Armed LED lights steady when
the exit-delay period ends.
All zones are armed.
Exit during the exit-delay
period.
Violating any zone after the
exit-delay period ends
triggers an instant alarm.
RF3341 Keypad [PIN][#][5] The LED flashes indicating a signal was
sent to your security system.
All zones are armed.
Exit during the exit-delay
period.
Violating any zone after the
exit-delay period ends
triggers an instant alarm.
RF3332/RF3332E,
RF3334/RF3334E
Not applicable