American Dynamics 8 Channel IP Encoder (M&H)
15-2 Camera Handler Release Notes
Changing streaming parameters like bit-rate, quality, frame-rate, key frame interval and others
would require the stream to be restarted, hence a small glitch in play out might be observed
during this time.
Focus and Iris is not supported by thin Client Web GUI, because 8 Channel Encoder supports
only relative value change and does not support absolute change of values. However it is
supported in Pattern.
Consecutive audio channel pairs should be configured with same codec otherwise RTSP will
send a 500 message. Pairing as below {PCMU,PCMA},AAC.
Due to the limitation in the Encoder firmware, the QCIF video stream uses the 172x112
resolution.
“Pattern” cancel feature is not supported in a consistent manner. During “Pattern Cancel”,
pattern recording is cancelled. Upon reinitiating the recording on a pattern, old recorded pattern
sequence is overwritten.
“Focus” and “Iris” support has been removed, to maintain consistency, the “Auto Iris” feature is
also disabled.
During Tilt having stopped at zero-tilt position in Dome camera where a flip of 180 degree
happens, might leads to the camera tilting continuously.
It has been observed that CBR operation for MPEG-4 at lower frame-rate settings is blocky and
full of artifacts. To improve the same, a constant quality settings operating as VBR is found to be
more effective. This has been incorporated in the solution.
Due to the limitation in the encoder, simultaneous PT and Z operation using the encoder on a
camera is not supported.
Due to the limitation in the encoder while operating in resolution QCIF, GOP settings 2 and in
CBR transmission mode, it is possible to observe up to 50% frame drops depending on the
complexity of input scene.
Bitrate / Quality or any streaming parameter changes using the encoder webpage does not
reflect or take effect on the already started or existing streaming session. Either the encoder
needs to be restarted or the streaming session needs to be restarted for these parameters to
take effect.
ADEIP8H PTZ zoom in feature can’t work with SpeedDome UD8( Pelco-P protocol).
ADEIP8H PTZ zoom in and zoom out feature can’t work with Pelco Dome(Pelco-D protocol).
ADEIP8H on rare occasions the MJPEG stream may send the bad frames that the fame size is
only several dozen bytes.
Note