FLIR
26-3
Limitations
Known Issues
Model Known Camera Limitations
1 F-Series
D-Series
PT-Series
Due to a necessity of FLIR camera video hardware re-start, it may
take about 48 seconds for the video stream to come back after any
stream property changes.
2 F-Series
D-Series
PT-Series
Camera may take more than 5s to respond to a CGI command, this
may cause NVR to timeout. This is camera performance issue.
3 F-Series
D-Series
PT-Series
User can only view camera’s video standard format setting (NTSC
or PAL) on NVR. We do not recommend the Video Standard be
changed from the default. This is due to the requiring FLIR camera
hardware change. The effect of changing the Video Standard are:
Incorrect Image Resolution and FPS will be displayed on Camera
WebGUI, NVR and victor Client.
4 F-Series
D-Series
PT-Series
NVR requires a response from cameras within 5 seconds. As a
result, changing resolution on the NVR may result an error
message. If the change is made again on the NVR it will work. The
error message is not always received.
5 F-Series
D-Series
PT-Series
MJPEG Live video Pixilated is caused by a low Q set by default on
the camera (Q=25). Once this value is set to 75 the Pixilation
disappears. The problem only arises with MJPEG.
6 F-Series
D-Series
PT-Series
After changing video channel resolution, frame rate and/or video
codec type on a stream, video stream will become unavailable for
about 45 seconds. This is because changing video channel
configuration parameters (Bitrate, Frame rate, Resolution and
Video Codec Type) requires reset of camera’s video hardware.
7 F-Series
D-Series
PT-Series
User is able to add camera to NVR using wrong password from
password group. This is because FLIR camera doesn’t require
authentication.
8 F-Series
D-Series
PT-Series
Video freeze may occur when changing heat distributions or many
moving objects are detected by camera. Wireshark traces shown
that the camera under test stops transmitting UDP/RTP packets for
a short period of time.
9 D-Series
PT-Series
Camera zoom in and zoom out only work on NVR. Camera zoom in
and zoom out do not work on Victor Client. This is because Victor
Client uses “Continuous Zoom” method to implement zoom in and
zoom out and FLIR cameras have no CGI support for continuous
zoom.
10 D-Series
PT-Series
Preset cannot be used to set Zoom In and Zoom Out.
PTScanListPointCurrentValuesSet is used to save a preset
position. This CGI does not save the zoom setting into the preset
position.
11 D-Series
PT-Series
F-Series
The video source format of FLIR cameras is pre-configured at the
factory. Switching the video source format through FLIR web or
Nexus interface will not take effect until the required FLIR camera
hardware components are installed. Customers must contact FLIR
to obtain the required hardware components and follow their
installation procedure.
Model Known Issues
F-Series Due to VE-API limitation, ZOOM only camera will not be supported as PTZ camera.
Therefore, ZOOM feature of F-Series will not be supported.
F-Series
D-Series
PT-Series
Communication channel between NVR client and camera server through port 8080
becomes unavailable occasionally. If HTTP connections through port 8080 cannot be
established, FLIR camera sever will not be able to respond to CGI commands sent by
NVR client. When this happens, user must try to re-establish the HTTP connection
through port 8080. Table 1 lists steps for trouble shooting HTTP connection between
NVR client and FLIR camera server (Nexus Server).
Page view 84
1 2 ... 80 81 82 83 84 85 86 87 88 89 90 ... 107 108

Comments to this Manuals

No comments