ACTi Corporation
21-2 Camera Handler Release Notes
Default Username & Password
Username: admin
Password: 123456
Supported Resolution
All resolutions less than or equal to 1280x720 are dynamically acquired by the camera.
Limitations
Resolutions larger than 720p are unsupported due to an incompatible algorithm used by the
camera when the stream's resolution is larger than 720p.
HUE feature on all cameras is unsupported, due to the manufacturer’s firmware team's
recommendation not to change HUE and not to use VIDEO_HUE command for ACTi cameras.
Due to camera limitation, the actual frame rate might be higher or lower than the requested
frame rate. (Please refer to ATP results).
For some cameras, RTP stream is not enabled by default. The handler will enable it before
creating the stream pipeline. Do not change the stream method while configured on the NVR.
By default, the B2 header function of the camera is enabled, which is not supported by the NVR.
Therefore, the handler will disable this function when a camera is added to the NVR. Don't
enable B2 header while camera is added to NVR.
Dry contact active state in NVR is read-only, this cannot be modified.
The scope of the image will be changed with a change of resolution, but the base pointer is
neither the image’s corner nor center.
The handler will use FPS as GOP. This is because when the camera streams on the RTP
protocol, GOP is fixed to 0, which means 1 key frame per second.
Due to the camera's FPS limitation. When single/dual streaming the FPS available is dependent
on several factors e.g. a codec or resolution change may cause FPS on both streams to change.
Due to the camera's limitation, camera will add to NVR with a lower FPS than supported. When
adding a dual streaming camera to the NVR both streams’ codec will be set to H.264 highest
resolution. Even if the second stream is not actively configured on the NVR, it is still affecting full
FPS performance on stream one – in order to extend stream one FPS
the user is required to
lower the resolution on stream two.
The hander will restart the stream when the resolution or codec is changed, which may cause a
video loss for a few seconds.
The contrast in camera web GUI displays as 0-100, but the vendor asked us to support 1 to 100,
so the contrast supported in NVR GUI is 1-100.
Focus and iris functions are excluded from support, because all cameras do not support them.
However it is possible that future cameras will support these functions.
WDR feature is currently not supported due to the related API VIDEO_WDR not working
correctly on the official release.
If the FPS is set to variable mode in the camera's web GUI, the NVR field for FPS will
automatically become read only.