4.3.3 Lens control cable
4.4 Housing mounting
1. Use two 1/4-20 x 0.50 in screws and 1/4 in spring washers
to mount the housing to a mount or a pan/tilt. The spring
washers must be used for the screws to thread properly.
2. The outermost set of 1/4-20 threaded holes are for mount-
ing to feed-through mounts, and the innermost 1/4-20
holes are for mounting to all other mounts and pan/tilts.
See Figure 4.1.
Cable type H05RN-F 3 G 0.75;
H05RN-F 3 G 1.00
Cable diameter (outer) 4.6 to 7.9 mm
(0.18 to 0.31 in)
Cable shape Round
Conductors 3 or 2
Voltage rating 300 V
Certificating authority VDE
Environmental Outdoor rated
Reference type Olflex rubber cable 1600 252;
Olflex rubber cable 1600 253
Table 4.4 Power cord specifications for Europe
Cable type Jacketed multiconductor cable
Cable diameter (outer) 4.6 to 7.9 mm
(0.18 to 0.31 in)
Cable shape Round
Cable shield Overall
Conductors 4 and 8
Conductor type Stranded 20 to 16 AWG
Conductor insulation Color coded
Table 4.5 Lens control cable specifications