Bosch UHO-HPS User Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
UHI/UHO Series Installation | en 19
Bosch Security Systems User Manual F.01U.026937 | V 2.0 | 2007.01
4.7.2 Conduit
These housings allow direct connection of conduit.
1. Remove the rear hole plugs and attach the conduit and
conduit fittings directly to the housing rear cap. The holes
accept either 3/8-inch NPT or 1/2-inch NPT conduit fit-
tings.
2. Any unused holes must be covered using the plugs pro-
vided with the housing.
4.7.3 Feed-through Wiring
Use feed-through mounts to feed cabling through the foot of
the housing.
1. Prior to mounting the camera, remove the two dome plugs
located inside the housing See Figure 4.6.
Fig. 4.6 Location of feed through wiring holes.
2. Screw the two 3/8-inch NPT fittings into the foot of the
housing.
3. Pull the cabling through the fittings into the housing.
Tighten the fitting to 4.0 Nm to 4.5 Nm (35 inch-lb to
40 inch-lb). This torque rating is approximately 1 to 1.5
turns past the point where the fitting starts to grip the
!
CAUTION! Always securely tighten all fittings to ensure a liquid-
tight seal. Failure to do so could allow water to enter the
housing and damage the camera and lens. If a sealant is used,
be sure it is a neutral cure type. Sealants that release acetic
acid may harm camera electronics. Use of drip loops is
recommended on the wiring outside of the rear end cap.
Holes
Page view 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 31 32