If the clamp is not properly connected, a waveform will still be displayed but
without cylinder numbers. If the spark plug cable is not available or the #1
cylinder doesn't ignite, the clamp should be connected to a spark plug cable
from another cylinder. The firing order will then be determined.
The firing order of 4-cylinder engine is usually 1-3-4-2. For example, when
the clamp is connected to #3 cylinder, the ignition waveform will be displayed in
a row as 3-4-2-1. Similarly, when connected to #2 cylinder, the order will be 2-
1-3-4 and when connected to #4 cylinder, the order will be 4-2-1-3.
b. Plug the other end to DS2020's channel 2 port
B. Menu Selection
If you select [1.PRIM] during the Primary Pattern Display, the Input Pattern
Selection menu will appear.
ILL. 4-17. Input Pattern Selection
Choose [2. SECONDARY], then Trigger Selection Menu will follow as shown in
ILL. 4-18.