ERROR MANAGEMENT
6 720 642 344 (2010/01)
21
8.5 ALARM WINDOW
8.5.1 TRIPPED LOW PRESSURE SWITCH
Fig. 49
POSSIBLE CAUSE 1: EVAPORATOR BLOCKED.
B Clean evaporator (Æ chapter 7.5).
B Select Acknowledge.
B Wait until the heat pump starts again.
B Notify customer service if the alarm occurs frequently.
POSSIBLE CAUSE 2: FAN BLOCKED.
B Remove debris that blocks the fan.
B Select Acknowledge.
B Wait until the heat pump starts again.
B Notify customer service if the alarm occurs frequently.
Possible cause 3: Refrigerant circuit fault.
B Select Acknowledge.
B Wait until the heat pump starts again.
B Notify customer service if the alarm occurs frequently.
8.5.2 TRIPPED HIGH PRESSURE SWITCH
Fig. 50
POSSIBLE CAUSE 1: AIR IN THE HEATING SYSTEM.
B Select Acknowledge.
B Check whether air is in the heating system.
B Fill the heating system and vent if required.
POSSIBLE CAUSE 2; BLOCKED PARTICLE FILTER:
B Select Acknowledge.
B Check filter.
B Clean filter if required (Æchapter 7.4).
POSSIBLE CAUSE 3: INADEQUATE FLOW RATE
ACROSS THE HEAT PUMP.
B Select Acknowledge.
B Check whether the primary heating circuit pump has
stopped.
B Check whether all valves are open. In a heating
system incorporating thermostatically controlled
valves, these valves must be fully open. In underfloor
heating systems, at least 50% of all heating loops
must be open.
B Where appropriate, select a higher speed for the
primary heating circuit pump.
B Notify customer service if the fault continues to occur.
8.5.3 FAILURE / SHORT CIRCUIT ON SENSOR
Fig. 51
All sensors connected to the heating installation can give
an alarm in the event of a fault. In the example, it is
sensor T3, hot water, which has given an alarm. All
sensors give alarms in the same way.
PROBABLE CAUSE 1; TEMPORARY FAULT:
B Wait.
PROBABLE CAUSE 2; DEFECTIVE SENSOR OR
INCORRECT CONNECTION:
B Notify customer service if the fault continues to occur.
8.5.4 FAULTY FUNCTION IN 4-WAY VALVE
Fig. 52
POSSIBLE CAUSE 1: 4-WAY VALVE FAULTY.
B Select Acknowledge.
B
Notify customer service if the alarm occurs frequently.
6 720 641 467-18.1I
6 720 641 467-19.1I
6 720 641 467-20.1I