All menus relating to temperature sensors
All menus relating to temperature sensors
All the menus associated with the heat pump temperature sensors are shown
below. Note that the user cannot make any changes to the settings in these
menus, only read the current values. Some menus are standard for all models
while others are only available in combination with different accessories. The
sensors give an alarm if the temperature is outside of the permitted range/
values.
Note
All sensors are not included as
standard on the heat pump, some are
available as accessories for different
application areas. See more informa-
tion under respective menus.
The menu shows the return temperature in the heating system, i.e. the water from the
radiators back to the heat pump. The temperature varies with the outdoor temperature.
The menu shows the outdoor temperature. Some deviation compared to the true tempera-
ture may occur due to thermal radiation from the house to the installed outdoor sensor.
The menu shows the set and present temperature in the lower section of the outer jacket
of the hot water cylinder T4 (GT4). The temperature is approximately 5ºC lower than the
temperature of the domestic hot water inside the inner cylinder.
The menu is only applicable together with a fl ow sensor. If an extra curve with mixing
valve is used, for example, for an underfl oor heating system, you can see the temperature
on the fl ow water in the circuit. The temperature varies with the outdoor temperature.
The menu is only applicable together with a room sensor. The menu shows the set point
value and present temperature in the room where the sensor is fi tted.
The menu shows the compressor’s working temperature. The temperature varies
between 70ºC and 125ºC during operations.
The menu shows the fl ow temperature of the central heating water as it leaves the heat
pump. It varies depending on the outdoor temperature and whether the heat pump is in
domestic hot water (DHW) heating mode.
The menu shows the temperature of the return water that is fed into the heat pump. It
varies depending on the outdoor temperature and whether the heat pump is in domestic
hot water (DHW) heating mode. The heat pump stops at 57ºC for safety reasons.
The menu shows the temperature of the heat transfer fl uid that is fed into the heat pump
from the collector system. It can vary between -5ºC to +15ºC during the year.
The menu shows the temperature of the heat transfer fl uid that is fed out of the heat
pump to the collector system. Normal operations should result in this being 1.5 - 5.0
degrees lower than the heat transfer fl uid that is fed into the heat pump.
Basic functions - Customer level 1
Temperature readings
Return radiator GT1
Off 41,3
O
Now 40,3
O
Return
Temperature readings
Out GT2
14,0°
Return
Temperature readings
Hot water GT3
Set 51,0°
Now 50,0°
Return
Temperature readings
Shunt, ow GT4
Tgt 40,3°
Now 43,0°
Return
Temperature readings
Room GT5
Tgt 20,0°
Now 19,5°
Return
Temperature readings
Compressor GT6
90,0°
Return
Temperature readings
Heat tr uid out GT8
45,0°
Return
Temperature readings
Heat tr uid in GT9
40,3°
Return
Temperature readings
Ht tr d(coll)inGT10
0,0°
Return
Temperature readings
Httr d(coll)outGT11
-4,0°
Return