D9412GV2/D7412GV2 | Operation and Installation Guide | 4.0 Installation
.
Bosch Security Systems, Inc. | 7/09 | F01U003641-04 19
4.6.3 Installing Modules and Relays
1. Power down the unit by unplugging the
transformer and disconnecting the battery.
Always power down the unit when
installing modules or relays, or when
making wiring connections to the control
panel.
2. Install and wire any modules required for the
installation as described in the module’s
installation instructions.
Instructions for the D8125 POPEX Module,
D8128D OctoPOPIT Module, D8129 OctoRelay
Module, D811 Arm Status Relay Module, and
D928 Dual Phone Line Switcher appear in this
guide.
Refer to Section 9.0 Off-Board Points on page
39 for D8125 and D8128D instructions. Refer to
Section 10.0 Off-Board Relays on page 53 for
D8129 and D811 instructions. Refer to Section
7.11 D928 Dual Phone Line Switcher on page 32
for D928 instructions.
3. If using the power outputs at Terminals 7 or 8,
refer to Section 6.4 Programmable Power Output
Terminals 6, 7, and 8 on page 28 for
instructions.
4.6.4 Connecting the On-board Points and
Keypads
Connect the on-board points and keypad wiring to the
system. Refer to Section 8.0 On-Board Points on
page 35 and Section 11.0 Arming Devices on page 58
for instructions.
4.6.5 Powering Up
Reconnect the battery, then plug in the transformer.
The buzzer sounds for two seconds when the control
panel is powered up. Leave the reset pin in the locked
position.
Yellow Charging Status LED Remains Lit: If the
yellow charging status LED remains lit after five
minutes of powering up the control panel, either the
battery is deeply discharged or too many powered
devices were connected to the control panel.
Combined continuous current draw for Terminals 3, 8,
24, and 32, and the accessory connector cannot
exceed 1.4 A. Refer to Section 6.0 Power Outputs on
page 28 for help.
4.7 Programming the Control Panel
If the control panel is not already programmed, review
the D9412GV2/D7412GV2 Program Entry Guide
(P/N: F01U003636). Ensure that all accessory
modules for desired features are available for
installation. Place the reset pin in the locked position
to copy or send information to and from the control
panel.
Use the D5200 Programmer or the RPS to load a
custom program into the control panel.
Move the reset pin to the normal position refer to
(Figure 6 on page 18). The control panel sends
Reboot and Battery Reports to the receiver if
programmed for reporting.
4.8 Installing the Point Chart Label
The point chart label is required for fire
systems with verifications points.
A point chart label is included in the literature pack.
Install the point chart label for fire or combined fire-
and-burglary systems that use verification points.
Use the D9412GV2/D7412GV2 Program Record
Sheet (P/N: F01U003635) to gather the necessary
information for completing the point chart. Fill out the
label and install it on the inside of the enclosure door
(refer to Figure 2 on page 15).
Avoid smearing the entries on the chart.
Use the peel-off backing to press the
label in place.
4.9 Testing the System
After installing and programming the control panel,
test the system completely. Test the control panel and
all devices for proper operation.
Test after initially programming the control
panel.
To meet UL 864 requirements, perform a
full system test after any subsequent
programming session.
Refer to Section 4.10 Service Walk Test on page 20
for complete Service Walk Test instructions.
Clear after Test: To clear the event memory and
report buffer, momentarily close the reset pin. Events
stored in the control panel’s event log are not cleared.