Installation Instructions
for the
DS1101i/1102i/1108i
Glass Breakage Detectors
1.0 Specifications
Coverage: 25 ft. (7.6 m) maximum to farthest point of glass
being protected. For glass sizes over 12 in. by 12 in. (0.3 m by 0.3
m); types of 1/4 in. (0.64 cm) Plate, Tempered, Laminated, and
Wired glass; and 1/8 in. (0.32 cm) Plate glass (DSB).
Mounting: Directly to the ceiling, on an opposite wall, or on an
adjacent wall.
Input Power: DS1101i/1102i: 12 VDC (6 VDC min. to 15 VDC
max.), 23 mA nominal @ 12 VDC (29 mA max. in LED latch
mode).DS1108i: 12 VDC (9 VDC min. to 15 VDC max.), 21 mA
nominal @ 12 VDC (24 mA max. in LED latch mode).
Standby Power: Connect to power sources capable of supplying
standby power of 23 mA-H for each hour of required standby time.
Four hour minimum standby time required for UL Certificated
installations.
Alarm Relay: DS1101i/1102i: Form “C” reed relay (NO/C/NC).
Contacts rated 3.5 Watts, 125 mA @ 28 VDC for DC resistive
loads. Protected by a 4.7 ohm resistor in the common “C”
leg.DS1108i: Normally Closed reed relay (NC/C). Contacts rated
3.5 Watts, 125 mA @ 28 VDC for DC resistive loads. Protected
by a 4.7 ohm resistor in the common “C” leg.
Tamper: Normally Closed (NC/C) rated 125 mA @ 28 VDC
maximum.
Operating Temperature: -20° to +120°F (-29° to +49°C). For
UL Certificated installations, the temperature range is +32° to
+120°F (0° to +49°C).
Enclosure: Round = DS1101i/DS1108i = 3.4 in. diameter by 0.83
in. D (8.6 cm diameter by 2.1 cm D). Square = DS1102i = 3.4 in.
H, 3.4 in. W, 0.83 in. D (8.6 cm H, 8.6 cm W, 2.1 cm D).
Accessories: DS1110i Glass Breakage Tester.
2.0 Installation Considerations
NOTE: Always pre-test the detectors location using the DS1110i
Glass Breakage Tester.
Do Not…
…Mount the detector with obstructions between the glass being
protected and the detector.
…Mount on the same wall as the glass being protected.
…Mount the detector closer than 5 ft. (1.5 m) to the wall that the
glass being protected is on, or any hard, sound reflecting surface.
…Mount closer than 2 ft. (0.6 m) to heating or cooling outlets;
mount as far away as possible. If drafts from these outlets
blow on the detector, select a different location for the
detector. Use the environmental test (see Section 4) to verify
good installation locations.
…Install on 24-hour protection circuits.
If you must install the DS1101i, DS1102i, or DS1108i in a zone
that is armed when occupied...
…Avoid acoustically live areas such as kitchens and bathrooms.
…Use a delay zone to provide the user time to acknowledge the
false alarms.
…Instruct system users how to respond to a false alarm.
Remember…
…The best mounting location is 10 to 20 ft. (3 to 6 m) from the
glass, in-line with the glass’s center, and on the ceiling or oppo-
site wall of the glass being protected. Do not exceed maximum
range.
…The detector should be within ±30° of the center of the glass to
be protected.
…Range will be reduced in areas that are acoustically soft. This
may be due to carpeting, drapes, plants, or other sound
absorbing materials. The DS1110i Glass Breakage Tester should
be used to verify range in all installations.
…Glass break detectors are intended only as a component of a
perimeter protection system. They should always be used in
conjunction with motion sensors.
…Glass breakage detectors are designed to detect the breakage
of framed glass and may not detect such things as bullet holes,
spontaneous breakage of glass (with no impact), and removal
of glass.
Maximum range:
The maximum detection range is 25 ft. (7.6 m) from the farthest cor-
ner, for glass sizes 12" by 12" (0.3 m by 0.3 m) and larger.
Hint: Tie a 25 ft. (7.6 m) string to the detector. The string should be
able to touch every part of the glass being protected. If any
part of the glass can not be touched by the string, it is out-
side of the detector’s coverage and additional detectors
should be used.
3.0 Selecting a Mounting Location
Opposite Wall Mounting
Mount the detector where there are no objects between itself and
the glass.
Do not mount the detector
closer than 5 ft. (1.5 m) to the
wall that the glass being
protected is on, or any hard,
sound reflecting surface.
The detector should be within
±30° of the center of the glass
to be protected (line B in Fig-
ure A).
Make sure the detector is no farther than 25 ft. (7.6 m) from any
corner of the glass (line A in Figure A).
Ceiling Mounting
The recommended location
is half the distance between
the glass and its opposite
wall or 2/3 of the rated range,
whichever is smaller.
Mount the detector where
there are no objects between
itself and the glass.
Mounting to drop ceiling tiles
is acceptable.
Do not mount the detector closer than 5 ft. (1.5 m) to the wall that
the glass being protected is on, or any hard, sound reflecting
surface.
Make sure the detector is no farther than 25 ft. (7.6 m) from any
corner of the glass (line A in Figure B).
The detector should be within ±30° of the center of the glass to
be protected (line B in Figure B).