AMAX panel 2000 / AMAX panel 2000 EN Summary | en 7
Robert Bosch Engineering and Business Solutions LimitedQuick Reference Guide F.01U.241.128 | V2 | 2011.11
1 Summary
1.1 Introduction
Thank you for choosing the AMAX Panel 2000/ AMAX Panel 2000 EN alarm host. This is a
flexible, reliable, convenien, and easy-to-use alarm system. This Quick reference guide is
provided with the system to give basic information about the basic system wiring,
components, and programming. As the system includes a large number of programmable
functions and options, we suggest reading the complete installation instructions. The
instructions introduce the system options, functions, and programming methods in detail.
1.2 Installation
This system must be installed by a qualified installer (please refer to installation
instructions).
During installation and wiring, the alarm host power source must be switched-off to prevent
equipment damage.After the alarm host wiring is completed, connect the AC power and
backup batteries (*backup batteries must be connected).The power light on the keyboard will
flash to show that the AC power is connected.
1.3 Programming
The programming and selections of this system are stored in non-volatile memory. Even when
the electricity is totally disconnected, this memory retains all information, and this
information can be modified many times if required.
1.4 Quick start
The following steps allow you to use the AMAX Panel 2000/AMAX Panel 2000 EN with factory
default values. To become familiar with programming AMAX Panel 2000/AMAX Panel 2000 EN,
read the information in.
1. Connect auxiliary equipment
2. After all wiring is complete, connect the AC plug pack and backup battery to the control
panel. The MAINS indicator lights signify AC mains supply is connected.
If any zone is unsealed when you power up the system, the corresponding zone indicator
is lit constantly.
Once you power up the panel, Date and Time has to be set.
All Faults and Tamper conditions have to be reset.
3. Enter the default user code (2580) + (98) and press [#] to enable the installer’s access.
4. Enter Date and Time. Refer to Section 1.6 Setting date and time on Page 9.
5. Enter the default Installer Code (1234) + (958) and press [#]. Two beeps sound and the
STAY and AWAY indicators flash simultaneously to indicate that you have entered into
installer’s programming mode. Once you enter the installer’s programming mode, you are
automatically positioned at location 000, the first digit of IP address / Primary telephone
number for Receiver 1.
6. Enter the IP address/Primary telephone number for Receiver 1 and then the port.
Programming a 15 in the telephone number indicates the end of the dialing sequence.
7. Program any other required changes. Otherwise, factory default settings are used.
8. Enter command [9 6 0] and press [#] to store the programming data and exit from
installer’s programming mode, a beep sounds and the STAY and AWAY indicators are
deactivated. The system is returned to the disarmed state and is ready for use.