WIRING
1. If you are replacing a thermostat, make note of
the terminal connections on the thermostat
that is being replaced. In some cases the wiring
connections will not be color coded. For
example, the green wire may not be connected
to the G terminal.
2. Loosen the terminal block screws. Insert wires
then retighten terminal block screws.
Caution
All components of the control system and the
thermostat installation must conform to
Class II circuits per the NEC Code.
Wire specications
Use shielded or non-shielded 18 - 22 gauge
thermostat wire.
BASE MODULE SUBBASE
INSTALLATION AND WIRING
Horizontal mount
Horizontal mount
Vertical mount
UP
Rh
Rc
G
Y1
Y2
D
C
O
B
W1/E
W2
H
Vertical mount
For vertical mount put one screw top and one
screw bottom. For horizontal mount put one screw
left and one screw right.
Caution
Wire the base module’s subbase the same
way you would wire a hardwired thermostat
subbase.
Caution
To establish communication from the base
module to master thermostat, refer to the
directions in the TSTBM3H2CPH6W-A
Thermostat-Base Module Communication
setup procedure below in this manual.
BASE MODULE—BASEMENT
INSTALLATION
Wireless Range
Range between the TSTBM3H2CPH6W-A and the
base module is up to 100 feet with no obstructions
and up to 50 feet in standard residential metal,
brick, and concrete construction. To extend the
range try placing the base unit higher if in a
basement or further away from large metal objects.
Do not install the base module in locations:
Where temperatures could exceed 150°F
That could be exposed to rain or snow
That could be exposed to freezing conditions
That are behind a chimney
Where high moisture is possible
Caution
The base module is NOT water or
weatherproof and should only be installed in a
conditioned space.
BASE MODULE—ATTIC INSTALLATION
Attic installation of the base module should be
avoided. Instead, locate a closet near the air
conditioning unit, then mount the base module high
on the wall inside the closet or on the ceiling of the
closet. This location will insure the base module is
below the 150ºF maximum ambient temperature
specication.
For vertical mount put one screw top and one screw
bottom. For horizontal mount put one screw left
and one screw right.
Failure to disconnect the power before
beginning to install this product can cause
electrical shock or equipment damage.
Caution
Mercury Notice: All Bosch thermostats are
mercury free. However, if the product you are
replacing contains mercury, dispose of it
properly. Your local waste management
authority can give you instructions on recycling
and proper disposal.