Installation
Perform the following steps to install the B450.
Notice!
Remove all power (AC and Battery) before making any connections. Failure to do so may
result in personal injury and/or equipment damage.
Setting the bus address
The B450 Conettix Plug-in Communicator Interface address switch provides the value for the
module's address. The figure below shows the address switch setting for address 1. Refer to
the table below for panel-specific settings.
Figure 4.1: Address switch set to address 1
Control panels
Switch
position
Control panel
bus address
Bus type Function
USB or SMS configuration
setting
0 N/A Any Change configuration
B5512/B4512/
B3512,D9412GV4/
D7412GV4/D7212GV4
1 1 SDI2 Automation, RPS, or Reporting
D9412GV4/D7412GV4/
D7212GV4
2 2 SDI2 Automation, RPS, or Reporting
D9412GV4/D7412GV4/
D7212GV4, D9412GV3/
D7412GV3/D7212GV3
4 88 SDI
1
RPS or Reporting
D9412GV4/D7412GV4/
D7212GV4, D9412GV3/
D7412GV3/D7212GV3
5 92 SDI
1
RPS or Reporting
1
For D9412GV4/D7412GV4/D7212GV4 configurations, SDI2 bus connection is the recommended configuration
option, but SDI bus configuration is also supported.
Table 4.1: B450 address switch settings
Insert the B44x communication module (required and available
separately)
Insert the desired B44x communication module into the slot of the B450 until you feel the
module “click” into place.
4
4.1
4.2