Send the Configuration SMS
1. Send the configuration SMS to the B44x module’s phone number. The transmission might
take several minutes. Because the bus address switch is set to 0, the B450 waits for an
SMS until a message is received.
2. Observe the LEDs on the B450. When the Transmit (TX) and Receive (RX) LEDs will flash
in unison at a 1 second interval indicating a successful SMS was received. If the SMS was
received but was not valid the Transmit (TX) and Receive (RX) LEDs will alternate flashing
at 1/2 second interval. Both flashing patterns will continue until the bus address switch is
moved from position "0.”
Notice!
If the LEDs indicate an invalid SMS, repeat the steps in Enter CONFIG MODE.
Refer to the tables in Maintenance and troubleshooting, page 39 section for more information
on LED descriptions. Ensure that your configuration SMS contains the correct information, as
well as sending the SMS to the correct phone number for the module, or use the USB
connection to configure the B450
Exit from CONFIG MODE
1. Change the bus address switch to the desired value, depending on the supported control
panel. Changes to the B450 configuration are accepted.
2. Check the signal strength and Heartbeat LED for status.
Firmware Update page
Firmware updates are performed through the USB interface via a communication program
such as Hyper Terminal or Tera Term.
Notice!
When performing a firmware update, verify that the update software file to be downloaded is
the most current software update version. No changes to the firmware occur if the firmware
update version is the same version as the current version installed on the B450.
1. Ensure that the USB cable is connected to the B450 and the target PC or laptop.
2. From Windows, start a terminal session by launching Hyper Terminal on Windows XP or
earlier, or launching Tera Term on Windows Vista/Windows 7/Windows 8.
3. Log into the USB interface as described in Log into the USB interface, page 25, starting at
step 3, and continuing through to step 6. The B450 USB login window appears, listing the
current software version and build.
5.5
Conettix Plug-in Communicator
Interface
Configuration | en 35
Bosch Security Systems, Inc. Installation and Operation Guide 2013.09 | 02 | F.01U.282.875