4.3 Polling Configurations
Plan carefully when selecting the control panel poll time, ACK wait times, control panel
retries, ITS-DX4020-G GPRS ACK timeouts, and D6x00 Receiver poll and ACK wait times.
Having the wrong or improper settings could cause trouble conditions when the network
carrier performs maintenance, and increased data volumes that could effect your monthly
cost. Your settings for these parameters determine how the system works, but depend on the
security level needed.
4.3.1 High Security Application (bank, jewelry store, UL fire, and so on)
Polling times are typically less than 20 min. Path integrity is critical, and short interruptions in
network service are indicated at the premise and central station. The following High Security
Application recommendation assumes the ITS-DX4020-G is the primary communication device
with no backup.
Control Panel Settings
Poll Rate: 60 sec
ACK Wait: 13 sec
Retry Count: 5
ITS-DX4020-G Settings
GPRS ACK Timeout: ACK wait (13) x Retry Count (5) + ACK Wait (13) = 78 sec
GPRS Session Timeout: Must be greater than control panel poll time (60 sec) + GPRS
ACK timeout (78 sec). The minimum GPRS session timeout setting is 1 hour; the default
4 hour setting is acceptable.
D6x00 Receiver Settings
Control Panel Poll Rate: 60 sec
ACK Wait: 78 sec