3.1.3 Tools Required
Straight slot screwdrivers ~ 2.5 mm (0.1 in.) - 3.1 mm (1/8 in.)
No. 2 Phillips screwdriver
Appropriate tool for cutting hole in drywall or ceiling tile
–Pliers
3.2 Pre-installation Check List
1. Determine the location and distance for the power supply box based on its voltage and
current consumption. See Chapter 4: Cable and Wire Standards for specifications.
2. Install all rough wiring including: power, control, video, alarms I/O, relay I/O, and fiber
optic cabling.
3. A minimum of 216-mm (8 1/2-inch) of air space above the ceiling is required to install the
In-Ceiling Mount.
3.3 Dimensions
Fig. 3.2 In-ceiling Dimensional Outline
!
WARNING! 24 VAC Class II power supply only.
mm
inches
210.7
8.30
19.0
0.75
153.9
6.06
150.2
5.91
94.0
3.70
176.8
6.96
204.3
8.04
DIA.