4 Cable and Wire Standards
4.1 Power
4.2 Wire Distance Guide for Pendant
115/230 VAC
Copper Wire To comply with local codes.
24 V to AutoDome
INDOOR ANALOG VA / Watts 14 AWG (2.5 mm) 16 AWG (1.5 mm) 18 AWG (1.0 mm)
100 Series 14 /7.5 248 m (813 ft) 156 m (512 ft) 98 m (322 ft)
200, 300 Series 18 / 10 193 m (632 ft) 121 m (398 ft) 76 m (250 ft)
500 Series 27 / 15 129 m (422 ft) 81 m (265 ft) 51 m (167 ft)
INDOOR ETHERNET VA / Watts 14 AWG (2.5 mm) 16 AWG (1.5 mm) 18 AWG (1.0 mm)
100 Series 21 / 11.5 165 m (542 ft) 104 m (341 ft) 65 m (215 ft)
200, 300 Series 25 / 14 139 m (455 ft) 87 m (287 ft) 55 m (180 ft)
500 Series 35 /19 99 m (325 ft) 62 m (205 ft) 39 m (129 ft)
OUTDOOR ANALOG
1
VA / Watts 14 AWG (2.5 mm) 16 AWG (1.5 mm) 18 AWG (1.0 mm)
100 Series 47 / 43.5 74 m (242 ft) 46 m (152 ft) 29 m (96 ft)
200, 300 Series 50 / 46 69 m (228 ft) 44 m (143 ft) 27 m (90 ft)
500 Series 55 / 51 63 m (207 ft) 40 m (130 ft) 25 m (82 ft)
OUTDOOR ETHERNET
1
VA / Watts 14 AWG (2.5 mm) 16 AWG (1.5 mm) 18 AWG (1.0 mm)
100 Series 52 / 47.5 67 m (219 ft) 42 m (138 ft) 26 m (87 ft)
200, 300 Series 54 / 50 64 m (211 ft) 40 m (133 ft) 25 m (83 ft)
500 Series 60 / 55 58 m (190 ft) 36 m (119 ft) 23 m (75 ft)
1. Standard heater module
Table 4.1 Maximum Wire Distances from Power Supply to AutoDome Pendant