When the pressure alarm is acknowledged using
OFF-65-ENTER, the flashing display will stop, but the letter "P"
will appear in the top right-hand corner of the monitor
(PHOTO 7D). This AutoDome will continue to display this
warning until the low-pressure problem has been corrected.
Photo 7D Low Pressure Alarm continued
7.3 Alarm Relay Output
The alarm relay output may be activated either manually, or
triggered when an Alarm occurs. There are three possible
choices for the time period that the relay output will remain
activated. These choices are:
1 Follow input: This means it mimics the state of the alarm.
As long as the alarm is active, the relay will be energized.
2 Latched: The relay will energize upon an alarm, and will
remain energized until the user issues the command
OFF-65-ENTER twice. The first time acknowledges the
alarm and removes the OSD (if programmed to display),
and the second time clears the alarm and resets the relay.
3 Specific length of time. This can be anywhere from
one sec to ten min. An OFF-65-ENTER that's entered
twice will again deactivate the relay, even if the timer has
not yet expired.
These choices are also listed in the Advanced Menu,
SECTION 12.
To manually activate the relay output from a Bosch
controller/keyboard, use the sequence of ON-65-ENTER. Use
OFF-65-ENTER to deactivate it.
The function of OFF–65-ENTER is different when the trigger
for the relay output is an alarm input. When the alarm input is
activated, the relay output will also be activated immediately.
When the alarm is acknowledged by OFF-65-ENTER, the first
time, the relay output will NOT deactivate. It will remain on for
the period selected in the menu. However, if OFF-65-ENTER is
entered a second time, the relay output will deactivate immedi-
ately, no matter what time period is set in the menu. This acts as
an alarm override, but the relay output will not activate again
until the Alarm has been cleared and another alarm occurs.
Example: Alarm 1 is set to be NORMALLY OPEN,
GO TO SHOT 1, OSD ON, and the output is set to be
triggered by Input 1 for a time period of 1 min, and is
connected to the Alarm Input of a digital recorder (DVR).
When the external contact is closed, the AutoDome will move
to SHOT 1, flash the word ALARM on the display, and activate
the relay output so the digital recorder starts recording. Pressing
OFF-65-ENTER would clear the flashing display and change to
the letter "A" in the upper right-hand corner, but the relay out-
put will still be on and the DVR still recording. After 30 sec, the
alarm input is still active, but if OFF-65-ENTER is pressed
again, the relay output will turn off and the DVR will stop
recording. The "A" is displayed until the alarm contact changes
state.