1.6 Attach the installation-assist cable* to the eyehook on the
top of the dome, and close the safety cable (see PHOTO
1F).
* A cable (user-provided) is recommended for safety
purposes when pipe mounting. See Mounting Guide for
instructions.
Photo 1F Connections
1.7 MAKE THE FOLLOWING CONNECTIONS:
**If the AutoDome is programmed for RS-485 operation, RXD
functions as DATA (+), and TXD functions as DATA (–).
Figure 1B Control connector
a. If the Alarm Inputs or the Relay Output are being
used, connect the appropriate wires to the 8-pin Alarm
connector (see FIGURE 1C).
Figure 1C Alarm connector
b. Connect Video (BNC) cable and the CONTROL
connector. Tighten screws on control connector.
c. When using Biphase, and the dome is in a star
configuration (or is the last dome on a daisy chain), it
requires a 110 terminating resistor (included) across
pin 8 (C+) and pin 9 (C–).
Daisy chain configuration is not possible if fiber optic
accessory is used.
1.8 AUTODOME 24 VAC INSTRUCTIONS
ENVX2450X, ENVX2460X, G3AX5X, and G3AX6X Kits
Check for the following:
a. An ENV-PSU (or equivalent) power supply must be
used.
b. Be sure to use an adequate gauge of 24 VAC wiring for
the distance run. See APPENDIX A - Power Wiring
Guide for proper wiring instructions and recommended
wire run lengths.
c. Wire the 9-pin CONTROL connector located on the
top of the unit, as in STEP 1G.
d. If the Alarm Inputs or Relay Output are being used,
connect the appropriate wires to the 8-pin Alarm
connector.
Figure 1D
If not using an ENV-PSU, place a jumper between
Pin (1) 24 VAC Hot and Pin (3) Heater (see
APPENDIX A for details).
1.9 Align the notch on the AutoDome with the notch on the
FRONT of the Pendant Arm.
Section 1
GND A1 A2 A3 A4 NC COM NO
87654321
ALARM CONNECTOR
ALARM GROUND
ALARM INPUT #1
ALARM INPUT #2
ALARM INPUT #3
NORMALLY OPEN
RETAINING SCREW
RELAY COMMON
NORMALLY CLOSED
ALARM INPUT #4
C–
Biphase
Ground
Biphase +
Biphase –
RS-232
Ground
**RS-232 TX
**RS-232 RX
24 VAC Neutral
Indoor Pendant - Not Connected
EnviroDome
®
- 24 VAC Heater
24 VAC Hot
C+ GND RXD TXD GND H
24 VAC
9 87654321
CONTROL CONNECTOR
Retaining
Screw
BNC Connector
Eyehook
8-Pin Alarm
Connector
9-Pin Control
Connector
Installation Assist Cable
**EnviroDome Only
Top of Dome
(1) 24 VAC Hot
(2) 24 VAC Neutral
(3) Heater**
(4) RS-232 Ground
(5) RS-232 TXD
(6) RS-232 RXD
(7) Biphase Ground
(8) Biphase +
(9) Biphase –
To ENV-PSU
or
equivalent