5.5.2 WEATHER-COMPENSATED CONTROL WITH
ROOM TEMPERATURE DEPENDENCE
Weather-compensated control with room temperature
dependence means that a temperature sensor
(accessory) is located in the lead room of the building.
The room temperature sensor is connected to the heat
pump and signals the current room temperature to the
control unit. The room temperature sensor influences
the heating curve flow temperature. The flow
temperature is reduced if the actual room temperature
is higher than the selected temperature.
A room temperature sensor is appropriate if, apart from
the outside temperature, other factors influence the
temperature inside the building, e.g. open fireplace, fan
heater, building subject to wind influence or direct
sunlight.
It is only the room where the room sensor is
located that can influence regulation of the
temperature.