Conettix D6600/D6100IPv6 | Program Entry Guide | 2.0 CPU Configuration
12
Bosch Security Systems, Inc. | 11/12 | 4998122702-07
Refer to Input and Output Ports in the
D6600/D6100IPv6 Operation and Installation Guide
(P/N: 4998122704).
2.2.29 CPU Programmable Input 2
Default: 0
Selections: 0 to 2
0 The UPS AC Lost or the Low Battery signal is
not monitored.
1 Monitoring the UPS AC Lost.
2 Monitoring the UPS Low Battery.
The D6600/D6100IPv6 is connected to an
uninterruptible power supply (UPS), and monitors the
AC Lost signal and the Low Battery signal supplied by
the UPS.
Refer to Input and Output Ports in the
D6600/D6100IPv6 Operation and Installation Guide
(P/N: 4998122704).
2.2.30 Receiver Number
Default: 01
Selections: 01 or 99
Enter the Receiver/Gateway Number.
2.2.31 Line Card Refresh
Default: 6
*
Selections: 0 to 20
0
Does not refresh regardless of the number
of No Data Received Reports.
1 to 6 After six consecutive No Data Received
Reports or Data Errors Reports the line
card refreshes.
7 to
20
The actual number of consecutive No
Data Received Reports or Data Errors
Reports before the line card refreshes.
* Needs at least six consecutive No Data Received Reports or
Data Errors Reports to perform a refresh.
Table 2: No Data Received and Data Error
Codes
D6500 Mode
SIA Mode
No Data
Received
X 63
[NUT04]
Data Error
X 62
[NYN]
Press the [ACKNOWLEDGE] button to clear the
output.
2.2.32 Time Zone
Default: 0
Selections: -12 to +14
Enter the offset from UTC for the Time Zone that the
receiver is located in. For example, -5 for the Eastern
Time Zone in the US.
Time Zone is the offset from Coordinated Universal
Time (UTC) by a whole number of hours.
2.2.33 External Parallel Printer
The D6600/D6100IPv6 needs an external parallel
printer. Refer to the operation and installation guide
for compatible printers. Enable, disable, or use the
parallel printer as a backup in case the computer
automation system fails.
Default: 3
Selections: 1 to 4
1
1
Primary: All reports go to this device.
2
2
Secondary: Reports go to this device only
after all primary devices fail.
3
2
Always On: All reports go to this device
whether or not it is functional.
4 Always Off: Device is disabled. No reports
are sent to this device.
1
Set this item to 1 to meet the requirements for UL
Burg/Automatic certification if you are not using a computer
automation system and have the parallel printer installed.
2
Set this item to 3 to meet the requirements for UL
Fire/Burg/Automatic certification if you are using a computer
automation system and have the parallel printer installed.
Page view 11