Conettix D6600/D6100IPv6 | Program Entry Guide | 3.0 Line Card Configuration
.
Bosch Security Systems, Inc. | 11/12 | 4998122702-07
3.1.9.2 Receiver Type (D6600 Only)
Default: 0
Selections: 0 to 9
0 Bosch Security Systems, Inc.
2 FBI CP220
Osborn-Hoffman Quick Alert I/II
4 Silent Knight 9000
6 Sur-Gard MLR2-DG
8 DMP
The selections made determine the database the
automation software uses to manage the incoming
signals from this specific line.
Setting the Receiver Type
2x
8x
repeatedly.
Program the automation switch for the
appropriate database.
• In D6500 Mode:
The D6600 sends the Receiver Type in the
header position of the report. When this option is
programmed with a non-zero value, it overwrites
the value set in Menu Item 2.4.8 Header on
page 17, in the D6500 Mode.
When this Option is 0, the header follows Menu
Item 2.4.8 Header.
When this Option is greater than 0, the “Header”
is 1” for “01” and so on. Every protocol in the
D6500 Mode shows a header.
• In SIA Mode:
When this Option = 0, the report does not contain
the receiver type modifier.
When this Option is > 0, the modifier “rc” in lower
case is sent at the beginning of each N and O
block.
Example: [#123|Nrc01BA1].
The Receiver Type applies only to Pulse
and DTMF formats in SIA Mode, except
High Speed and Contact ID.