Conettix D6600/D6100IPv6 | Program Entry Guide | 2.0 CPU Configuration
.
Bosch Security Systems, Inc. | 11/12 | 4998122702-07
17
2.4.4 Parity
Default: 0
Selections: 0 to 2
0 None
1 Even
2 Odd
Set the parity for the COM3 port.
2.4.5 Stop Bit
Default: 1
Selections: 1 or 2
Select the stop bit value for the COM3 port.
2.4.6 Link Test
Default: 30
Selections: 00 to 99
00 Do not send the Link Test to the
automation system PC.
01 to
99
Send the Link Test to the automation
system PC.
The selection determines the number of seconds the
automation system PC waits between sending and
accepting a Link Test. The Link Test confirms if there
is communication between the automation system PC
and receiver.
2.4.7 Automation Wait
Default: 04
Selections: 01 to 60
Enter the amount of time in seconds the
D6600/D6100IPv6 waits for the ACK message from
the automation system PC.
2.4.8 Header
Default: 00
Selections: 00 to FF
00 No header character output.
Set the header character for the D6500 Mode
automation format (hexadecimal).
2.4.9 Trailer
Default: 14
Selections: 01 or FF
Set the trailer character for the D6500 Mode
automation format (hexadecimal).
2.4.10 BFSK Fire Bit
Default: 0
Selections: 0 or 1
0 Fire messages are sent to the automation
PC as standard alarms, troubles, and
restorals.
1 Fire messages are sent to the automation
PC with the digit character codes as shown
in Table 3 (refer also to the
D6600/D6100IPv6 Computer Interface
Manual [P/N: 4998122703] for the digit
character codes). If set to 1, you must
restructure your automation account
database to accept the new event codes. If
this is not done, fire messages might
appear as unlinked messages.