Normal Operation Mode
In Normal Operation Mode, the D6600/D6100IPv6 sends messages immediately or in blocks to
reporting devices (such as printers and computers) as soon as the devices are ready to
receive the information. Signals do not remain visible in the display. If all reporting devices
fail, the D6600/D6100IPv6 reverts to Manual Mode until a device returns to service. Normally,
the D6600/D6100IPv6 sounds the Operator Alert Buzzer for new events received when the
automation link fails.
Typical Alarm Receiving Sequence
1. An alarm occurs on Zone 3 at subscriber location 456. The user programs Account 456 to
report to Line 01 and does not assign Line 01 to report to a call group.
2. The OL LED glows green when the receiver answers the call and receives data.
The primary reporting device (such as an external printer or automation computer)
activates. If the external printer is a primary reporting device and Line 01 is not assigned
to Group Reporting, it prints.
3. If Line 01 is assigned to group 1 Reporting, the receiver’s external printer prints:
4. Line 01 hangs up.
Operating in Manual Mode
If all reporting devices (such as printers and computers) fail, the D6600/D6100IPv6 reverts to
Manual Mode until a device returns to service.
D6600/D6100IPv6
The D6600/D6100IPv6 receives signals while in Manual Mode. The Operator Alert buzzer
sounds.
1. Press the Acknowledge button to shut off the operator alert buzzer.
Shuts off the operator alert buzzer
Compare the display to the printout to confirm you read the data correctly.
(For each alarm event, press the Acknowledge button twice; once to acknowledge the
alarm and once to print the event. As you step through this process, the event number
will diminish.)
2. Press the Acknowledge button to send the message to a connected printer.
3. Press the Acknowledge button.
Sends the message to a connected printer.
4. Press the Acknowledge button.
5. Press the Acknowledge button.
Sends the message to a connected printer.
6. Press the Acknowledge button.