Bosch D6100IPv6 Specifications Page 44

  • Download
  • Add to my manuals
  • Print
  • Page
    / 88
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 43
1 2 4 8
1
2
3
4
5
6
7
8
9
10
11
12
13
11
14
15
Figure 12.2: Conettix Network System Connection diagram – D9133TTL-E/DX4020 and Bosch Control
Panels
Callout Description
Callout Description
1 Bosch Control Panels 9 D6100IPv6
2 Connection – control panel serial device
interface (SDI) bus to D9133TTL-E or DX4020
bus terminals
10 Connection – Ethernet hub to
Network Ethernet Module
3 D9133TTL-E or DX4020 Network Interface
Module
11 Network Ethernet Module
4 Connection – D9133TTL-E or DX4020
Ethernet port to Ethernet hub
12 Connection – Network Ethernet
Module to D6600 COM4 port
5 Host PC running D6200 Programming
Administrative Software
13 D6600
6 Connection – Ethernet hub to Host PC
NIC
14 Connection – second Network
Ethernet Module to D6600 COM 1 port
(optional)
44 en | Network Communications
Conettix Communications Receiver/
Gateway
2012.11 | 08 | 4998122704 Installation and Operation Guide Bosch Security Systems, Inc.