2.2.21 Buzzer
Default: 3
Selections: 0 to 4
0 Buzzer off
1 Buzzer on for any events
2 Buzzer on for system trouble conditions
3 Buzzer on for new events when the
automation link fails or any system trouble
conditions occur
4 Buzzer on for new events when printer link
fails or any system trouble conditions occur
2.2.22 Armed Status
Default: 0
Selections: 0 or 1
0 Armed Status of D4112/6112 does not print
at test time.
1 Armed Status of D4112/6112 prints at test
time.
2.2.23 Busy Seconds Reports
Default: 1
Selections: 0 or 1
0 No Busy Seconds Reports.
1 Busy Seconds Reports for UL applications.*
* Set this item to 1 to meet the requirements for UL
certification. Refer to Busy Seconds Reports in the
D6600/D6100IPv6 Operation and Installation Guide
(P/N: 4998122704).
2.2.24 Report Grouping
Default: 0
Selections: 0 or 1
0 Prints messages as the D6600/D6100IPv6
processes them.
1 Stores messages, then prints when the
D6600/D6100IPv6 completes the call.
Report Grouping stores the incoming messages (up
to 40, depending on the format and the Maximum On
Line Time option) until the call completes. Then the
D6600/D6100IPv6 sends the group of messages from
the same call to the reporting devices. Report
Grouping prints messages in the order the
D6600/D6100IPv6 processes them.
2.2.25 Point/User Text
Default: 1
Selections: 0 to 2
0 No Point and User ID Text
1
Send Point and User text only to the printer
2 Send Point and User text to both the printer
and automation software.*
* This option works in SIA Mode Automation only.
Print Point Text and User Text on the external printer
and automation software.
2.2.26 CPU Programmable Output 1
Default: 0
Selections: 0 or 1
0 Disable the output
1 Turns output on when the COM3
automation link fails.
Outputs 1 and 2 can now signal when the COM3
automation link fails.
Press the [ACKNOWLEDGE] button to clear the
output.
Refer to Input and Output Ports in the
D6600/D6100IPv6 Operation and Installation Guide
(P/N: 4998122704).
2.2.27 CPU Programmable Output 2
Default: 0
Selections: 0 or 1
0 Disable the output
1 Turns output on when COM3 automation link
fails.
Outputs 1 and 2 can now signal when the COM3
automation link fails.
Press the [ACKNOWLEDGE] button to clear the
output.
Refer to Input and Output Ports in the
D6600/D6100IPv6 Operation and Installation Guide
(P/N: 4998122704).
2.2.28 CPU Programmable Input 1
Default: 0
Selections: 0 to 2
0 The UPS AC Lost or the Low Battery signal is
not monitored.
1 Monitoring the UPS AC Lost.
2 Monitoring the UPS Low Battery.
The D6600/D6100IPv6 is connected to an
uninterruptible power supply (UPS), and monitors the
AC Lost signal and the Low Battery signal supplied by
the UPS.
Page view 10