ELECTRICAL CONNECTIONS
6 720 806 768 (2013/02) 31
14.2.6 COMPLETE WIRING DIAGRAM CONNECTIONS
Fig. 37 Complete wiring diagram connections (230V)
Solid line = factory set connection
Dotted line = connect during installation:
[RHP] High pressure switch
[F11/Q1] Motor cut-out compressor/soft starter
[F1/F21] Fuse/overheat protection electric additional heat
[K2] Contactor electric additional heat stage 1
[K3] Contactor electric additional heat stage 2
[E11.G1] Circulation pump circuit 1
[G2] Heat carrier pump
[G3] Collector circuit pump
[Q21] 3-way valve
[F51] Fuse 6.3A
[E11.P2
1)
] General alarm
[E41.G6
1)
] Circulation pump hot water
[E12.Q11] Extra mixing valve circuit 2
[E12.G1] Circulation pump circuit 2
[R1] Relay
1) P2- P2 potential free connection for cirkulation pump / general alarm
E12.G1: When a low energy pump is connected, an
external control relay must be used. The pump is
connect to the power grid with a dedicated supply.