FACTORY SETTINGS
6 720 806 768 (2013/02) 65
Circuit 2, 3... Mixing valve mode Off 1
Type of heating system
Underfloor 1
Highest permitted flow temperature T1
Radiator/Underfloor 80/45 °C 1
Lowest permitted flow temperature T1
10 °C 1
Heat curve
0
Room sensor (room controller)
Som Circuit 1 Heating 0, 1
Room temperature program
As Circuit 1 Heating minus Copy to all heating circuits 0, 1
Regulator settings
P constant
I constant
D constant
Minimum PID signal
Maximum PID signal
Mixing valve running time
Mixing valve fully closed
Mixing valve start closing
1,0
300
0.0
0%
100%
300s
2.0K
2.0K
1
1
1
1
1
1
1
1
General Summer/winter operation Winter operation
Outdoor temperature limit for change over
Delay before change over to winter operation
Delay before change over to summer operation
Direct start limit for winter operation
Automatic
18 °C
4h
4h
13 °C
0
0
1
1
1
Maximum operating time for heating at hot water
demand
20min 1
Minimum outdoor temperature
-35 °C 1
Room temperature F value Access level
Table 174 Factory settings Room temperature
Hot water F value Access level
Acknowledge hot water sensor T3 (Auto) 1
Extra hot water Extra hot water duration
Extra hot water stop temperature
0h
65 °C
0
0
Hot water peak Day of the week
Interval in weeks
Start time
Maximum time
Time for warm-keeping
Wednesday
1
3:00
3.0h
1.0h
0
0
0
1
1
Hot water program Active program
View/edit active program
Always hot water 0
0
Hot water mode Economy 0
Hot water settings heat pump x Hot water production Yes/No 1
Block heating during hot water demand No 1
Maximum operating time for hot water at heating demand 30 min 1
Hot water circulation pump active No 1
Protective anode installed Yes/No 1
Table 175 Factory settings Hot water
External control F value Access level
Heat pump x External input 1, 2 Invert input No 1
Block additional heat 100% at trigged power guard No 1
Max output additional heat at trigged power guard Off 1
Block compressor x No 0
Block additional heat No 0
Block heating at tripped underfloor temperature limiter No 1
Block heating No 0
Room temperature No (0,0 °C) 0
Block hot water production No 0
Start collector circuit pump No 1
Alarm at low pressure in collector circuit No 1
External input circuit 2, 3... Invert input No 1
Block heating at tripped underfloor temperature limiter No 1
Block heating No 0
Room temperature No (0,0 °C) 0
Table 176 Factory value External control
Page view 64